Maintenance
Page 4-5
Error Codes
When an error has occurred, “ERROR #” will appear on the text display alternating with the message
“OUT OF ORDER.”
NOTE: Log number will show in the Incline Display as L-01 through L-20.
Press CLEAR button and hold to clear all errors in log. The display reads “NO ERRORS” when log is empty.
Press enter to exit out.
NOTE: See contact information in Chapter 5 – Customer Service for all maintenance and service activities.
Incline and low battery errors are as follows:
Error Number Cause Display Reset/Remedy
24: Incline
moving
too slowly
Incline is commanded to move,
yet the change in feedback
is slower than the minimum
allowed.
None, stored error only Inspect and lubricate the
lead screw.
Re-calibrate the incline.
Measure the incline
potentiometer output.
The potentiometer
could be ‘bad’.
Replace the battery.
25: Incline
movement
feedback
stopped
Incline is commanded to move
yet the feedback indicates the
value is not changing or ceases
to change as expected.
Dashes shown in incline
window.
Display attempts to
re-calibrate incline position
on entry to Dormant Mode.
26: Incline
disabled
Incline feedback problems could
not be remedied by
re-calibrating after an Error 25.
Dashes shown in incline
window. Incline is
disabled.
Contact service technician.
27: Low
Battery
Battery voltage is reported to be
below the limit of 10.7v DC and
the controller has issued the low
battery warning.
Dashes shown in incline
window. Incline is
disabled.
Further use will re-charge
the battery and the error
condition will be cleared
automatically.